Manufacturer ModelP10090-01
Ordering Information
Contact Daisuki for pricing, lead time, and availability. Our team will provide specific details based on your application and order requirements.
MOQ1 pc
Resources
| Wavelength Range | 0.9–3.65 µm |
| Peak Wavelength | 3.35 µm |
| Detection Mechanism | Photovoltaic |
| Material / Structure | InAs |
| Responsivity | 1.0 A/W |
| Detectivity (D*) | 4.5×10⁹ cm·Hz½/W |
| NEP | ~2×10⁻¹¹ W/√Hz |
| Quantum Efficiency / PDE | High |
| Output Signal | Analog current |
| Active Area / Pixel Size | φ1 mm |
| Response Time / Bandwidth | 0.7 µs |
| Dark Current / DCR | Low dark current (nA range) |
| Gain / Breakdown Voltage | None / PV mode |
| Bias / Operating Voltage | 0 V (photovoltaic / optional bias) |
| Package / Form Factor | Metal can package |
| Window / Optical Interface | IR glass window |
| Cooling Requirement | No cooling required |
| Operating Temperature | -20°C to +60°C |
| RoHS / Compliance | RoHS |
Main Applications
CO₂ gas sensing, MWIR spectroscopy
Typical Instruments
FTIR, NDIR analyzers
Room-temp 3 µm band detection, low noise InAs
Have Questions? Let's Talk.
Reach our sales team for pricing, availability, or technical consultation.